Ion Pump Controllers

MPC

MPC

Ordering PN:

Description:

Price:


Bookmark and Share

HV Channels

Configurable for 1 to 4 output connectors.  Multiple Ion pumps running on one high voltage supply operate in parallel.

Configurable for 1 to 4 output connectors. Multiple Ion pumps running on one high voltage supply operate in parallel.

HV Channels

Configured with two outputs per HV channel.  Multiple Ion pumps running on one high voltage supply operate in parallel.

Configured with two outputs per HV channel. Multiple Ion pumps running on one high voltage supply operate in parallel.

HV Polarity

Postive polarity is applied to Diode style pumping elements

Postive polarity is applied to Diode style pumping elements

HV Polarity

Negative polarity is applied to Triode syle pumping elements

Negative polarity is applied to Triode syle pumping elements

Connector Style

The 10 kV SHV output is standard  for current and historical controllers

The 10 kV SHV output is standard for current and historical controllers

Connector Style

Available Fischer with Interlock for existing Varian/Agilent pump installations

Available Fischer with Interlock for existing Varian/Agilent pump installations

Connections/Channel

One Output per Channel (10kV SHV shown)

One Output per Channel (10kV SHV shown)

Connections/Channel

Two Outputs per Channel  (10kV SHV shown)

Two Outputs per Channel (10kV SHV shown)

Connections/Channel

Single Channel with Three Outputs (10kV SHV shown)

Single Channel with Three Outputs (10kV SHV shown)

Connections/Channel

Single Channel with Four Outputs (10kV SHV shown)

Single Channel with Four Outputs (10kV SHV shown)

Input Voltage

110-volt, US Connector

110-volt, US Connector

Input Voltage

220-volt, US Connector

220-volt, US Connector

Input Voltage

230-volt, European Connector

230-volt, European Connector

Input Voltage

230-volt, United Kingdom Connector

230-volt, United Kingdom Connector

Input Voltage

230-volt, Australian Connector

230-volt, Australian Connector

Communications

Standard ethernet communications and browser support.

Standard ethernet communications and browser support.

Communications

Standard RS232 Protocol

Standard RS232 Protocol

Communications

Standard RS422 Protocol

Standard RS422 Protocol

Communications

Standard RS485 Protocol (Half Duplex)

Standard RS485 Protocol (Half Duplex)

Communications

Standard RS485 Protocol (Full Duplex)

Standard RS485 Protocol (Full Duplex)

Remote Enable

High voltage or TSP can be controlled by alternate controller set-points

High voltage or TSP can be controlled by alternate controller set-points

Remote Enable

Select to control high voltage or TSP using alternate controller set-points

Select to control high voltage or TSP using alternate controller set-points

TSP/NEG Control

Select Remote TSP/NEG control to add TSP/NEG control harware.  Coming in early 2016 to the QPC!  Contact Gamma Vacuum for details.

Select Remote TSP/NEG control to add TSP/NEG control harware. Coming in early 2016 to the QPC! Contact Gamma Vacuum for details.

TSP/NEG Control

Control a TSP from the MPC

Control a TSP from the MPC

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a dual remote TSP/NEG controller over long distances.

Interface with a dual remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Interface with a remote TSP/NEG controller over long distances.

Interface with a remote TSP/NEG controller over long distances.

TSP/NEG Control

Control a NEG from the MPC

Control a NEG from the MPC

Unit Options

HV Channels



HV Polarity




Connector Style



Connections/Channel






Input Voltage






Communications







Remote Enable



TSP/NEG Control








Specifications

Weight: 16.8 (37) min., 25.4 (56) max. kg (lbs)
Shipping Weight: 32 (66) kg (lbs)
Dimensions: 483 x 133 x 476 mm, l x w x d
Input Power: 120 or 220/48-62 volts/Hz
Output: +7000 (CV/DI), -5600 (TR) volts
Output: 500 current (mA)
Power: 1000 maximum Watts
Resolution: 0.1 uA
Output Connectors: 1-4 10kV SHV or Fischer
Display Type: 1/4 VGA LCD w/touchscreen
Analog Voltage Ouput: 1V per 1000V
Analog Current/Pressure Output: user configurable
Set Points: 4 TTL, 4 Relay
Humidity: 0 to 80% RH, noncondensing
Temperature: 0 to 40 deg C
Communications: RS232, RS422, RS485
Conformity to Norms: EN61000-6-1, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN 61010-1